High flow hose peristaltic pump in Russia is a positive displacement pump with low speed, high efficiency and noiseless characteristics, and has a wide range of applications. The working principle is mainly that a pair of rollers rotate in the lubricated pump cavity. These rollers and the wall of the high flow peristaltic pump in Russia housing cavity push the hose together and squeeze it. As the roller rotates, the flat part of the hose gradually moves from the inlet end to the outlet end of the pump. In this process, the liquid-filled hose gradually recovers its original shape due to its own elastic effect, and the volume becomes larger, generating a vacuum to suck the material, and the liquid-filled hose gradually becomes squeezed, and the volume becomes smaller It is forced to discharge, and then repeat the action for pumping.
The main functions of the high flow hose peristaltic pump:
1. Low speed, no noise, can run back and forth.
2. Unique structure, no seal, no leakage.
3. Self-priming is possible, and has a strong self-priming ability.
4. Simple structure and convenient maintenance.
5. It can transport corrosive slurry and sludge with high content of particles, fibers and other impurities.
6. The medium flow rate is low and there is no shearing force. This is especially suitable for carrying materials that are sensitive to shear forces.
7. It can transport high-viscosity media, and can also transport gas, liquid and solid three-phase mixed media in large capacity.
8. By adjusting the speed of the pump, the flow can be adjusted without changing the outlet pressure of the pump.
When using the high flow hose peristaltic pump in Russia, we should keep the following points in mind:
1. If the high flow peristaltic pump in Russia does not work, you can loosen the pressure block on the pressure tube of the peristaltic pump to extend the service life of the pump tube.
2. When choosing a high flow peristaltic pump in Russia, if the discharge flow is satisfied, the pump speed should be as low as possible below 300 rpm.
3. For the head of high flow peristaltic pump in Russia, we should use a dedicated tube, and for other interfaces, we can use a common tube.
4. The inlet of the peristaltic pump pipe should be as short as possible, and the joint and diameter of the peristaltic pump pipe should not be lower than the pipe diameter of the peristaltic pump pump head.
5. When we using, you must carefully clean the surface of the pump casing that is in contact with the pump tube and pump tube debris, especially the pressure block of the pressure tube.